BPMMS - 1657-12S, BLUE SHOWER

  • MSDS: BPMMS
  • Manufacturer: TECH SPRAY INC
  • Product Name: 1657-12S, BLUE SHOWER
  • National Stock Number: 9150-01-302-4260
Product Identification

Product ID:1657-12S, BLUE SHOWER
MSDS Date:11/22/1985
FSC:9150
NIIN:01-302-4260
MSDS Number: BPMMS

Responsible Party
TECH SPRAY INC
88 HUGHES ST
AMARILLO, TX 79105
US

Emergency Phone: 800-692-4677;806-372-8523

Info Phone: 800-692-4677;800-858-4043

Preparer: G. UNRUH

Cage: DO677

Contractor
TECH SPRAY INC
949 AMARILLO, TX 79105-0949 US

Telephone: 806-372-8523

Cage: DO677

Ingredients

ISOPROPYL ALCOHOL; (ISOPROPANOL)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 2.09%

OSHA PEL 400 PPM;500 PPM STEL

ACGIH TLV: 400 PPM;500 PPM STEL


METHANE, TRICHLOROFLUORO-; (TRICHLOROMONOFLUOROMETHANE)

CAS: 75-69-4

RTECS: PB6125000

Fraction By Weight: 59.58%

OSHA PEL 1000 PPM

ACGIH TLV: C, 1000 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANE,1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 37.08%

OSHA PEL 1000PPM, 1250 STEL

ACGIH TLV: 1000PPM, 1250 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: LIGHTHEADEDNESS. SKIN/EYES:
DEFATTING OF LIPID TISSUE. CHRONIC: NOT KNOWN. CHLOROFLUOROCARBON
MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS
& COULD HAVE SIMILAR EFT IN HUM ANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE)MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
IN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CFC'S.
Medical Cond Aggravated by Exposure:CARDIAC ARRYTHMIA.

First Aid

First Aid:INHAL: MOVE TO FRESH AIR. SKIN: WASH WITH CLEAR WATER FOR 15
MIN. EYES: WASH WITH CLEAR WATER FOR AT LEAST 15 MIN. INGEST: CALL
MD IMMED .

Fire Fighting

Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DO NOT STORE CANS IN DIRECT SUNLIGHT OR
ABOVE 120F. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL,
CHLORIDES, FLUORIDES & PHOSGENE .

Accidental Release

Spill Release Procedures:TAKE UP ON SUITABLE ABSORBENT AND PLACE IN
APPROPRIATE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE CANS IN DIRECT SUNLIGHT
OR ABOVE 120F.
Other Precautions:USE PRODUCT ACCORDING TO LABEL INSTRUCTIONS. NO
SMOKING IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF ARC
WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION MAY
CAUSE FORMATION OF HCL, C HLORIDES, FLUORIDES & PHOSGENE .

Exposure Controls

Respiratory Protection:NONE. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: X7FT. 3/MIN.
Protective Gloves:BUNA.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:874F, 46.8C
Spec Gravity:1.402(H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR AND WATER WHITE LIQUID, LOW ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
REACTIVE ALKALI METALS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HCL, HF, COCL*2. CHLORIDES, FLUORIDES
& PHOSGENE .

Disposal

Waste Disposal Methods:CONSIGMENT TO RECLAIMER. DISPOSE OF IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.